Slab connection to curved walls

Detail: Slab connection to curved wallszoom

Areas with curved walls: Slide MD compensation beams (3) into the MD primary beams and place props with H20 beams (4) along the curved wall. Place the facing (2) for the filler area onto the MD compensation beams and H20 beams. Use several short H20 beams for wall curves with a small radius. 

Other filler areas: Use H20 beams and a facing cut to size. Depending on the width of the filler area, the spacing of H20 beams may be limited to max. 50 cm. 

(1) MevaDec panel
(5) Prop with drop head

 

References

 

MevaDec product page

MevaDec product page

Contact Form

 
 
 

Product List

 
 

Note that each building project will vary in terms of the number of parts needed. If you need assistance in planning the pour, please consult with us via the contact form.

 
 